Sollatek Maxima 3kVA




Uninterruptible Power Supply for Computers, Servers, Modems, Routers, TVs, Multimedia, Cash Machines, Satellites/VSAT & Telephones

  • Output power factor 0.8
  • Wide input voltage range (110v – 300V)
  • Programmable power management outlets


Qty


  Availability

This product may be Available with a discount via Pc Builder only.

Description

A true double conversion UPS, Maxima will provide clean, high level quality power to fully protect mission-critical devices such as sensitive networks, small computer centres, servers, telecom applications, as well as industrial applications.

  • 50/60 Hz Frequency Converter Mode
  • ECO made operation for energy saving
  • Emergency Power Off (EPO) Function
  • SNMP+USB+RS-232 multiple communications
  • Higher accuracy for output voltage
  • Smart battery charger design to optimise battery performance
  • DSP technology applied for 6K and up models
  • Maintenance bypass available for 6K and up models
  • Optional N+X parallel redundancy available for 6K and up models
  • Adjustable battery numbers for 6K and up models
  • Built in isolation transformer (Option)

3000VA 2400W @ FULL LOAD 10MIN

Data sheet

Voltage Protection
Online Double Conversion UPS

Specific References

PHASE                                                Single phase with ground

CAPACITY*                                         3000 VA / 2400 W

Nominal Voltage                                   100/110/115/120/127VAC or 200/208/220/230/240VAC

Input Voltage Range                             55-150 VAC or 110-300  (Based on load at 50%) 85-140VAC or 160-280V (Based on load at 100%)

Frequency Range                                  40Hz ~ 70 Hz

Power Factor                                         0.99 @ Nominal Voltage (100% load)

OUTPUT

Output Voltage                                      100/110/115/120/127VAC or 200/208/220/230/240VAC

Voltage Regulation                                 ± 1%

Frequency Range(Synchronized Range)   47~ 53 Hz or 57 ~ 63 Hz

Frequency Range    (Batt. Mode)             50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz

Current Crest Ratio                                3:1

Harmonic Distortion                               3 % THD (Linear Load)

                                                            6 % THD (Non-linear Load)

Transfer Time

AC Mode to Battery Mode                       Zero

Inverter to Bypass                                 4 ms (Typical)

EFFICIENCY

        AC Mode                                       90%

        Battery Mode                                 88%

BATTERY

Standard Model Battery Type                  12 V / 9 AH
     Numbers                                          6
 Typical Recharge Time                          4 hours recover to 90% capacity
 Charging Current (max.)                       1A
 Charging Voltage                                  82.1 VDC ±1%

INDICATORS

LCD                                                     Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators
ALARM

Battery Mode                                        Sounding every 4 seconds
Low Battery                                          Sounding every second
Overload                                              Sounding twice every second
Fault                                                    Continously sounding
PHYSICAL

Standard Model Dimension, D x W x H (mm) 421 x 190 x 318
Net Weight (kgs)                                         27.6 61

ENVIRONMENT

Humidity                                                  20-90 % RH @ 0- 40°C (non-condensing)
Noise Level                                              Less than 50dBA @ 1 Meter


MANAGEMENT

Smart RS-232/USB                                     Supports Windows 2000/2003/XP/Vista/2008/7/8, Linux, Unix, and MAC
Optional SNMP                                           Power management from SNMP manager and web browser